Effect of Digestion Method, Siderite Content, and Fizz Rating on Neutralization Potential of Overburden Samples

Agricultural & Natural Resources Development Home Page | Land Reclamation Home Page | Effect of Digestion Method, Siderite Content, and Fizz Rating on Neutralization Potential of Overburden Samples

Table 7. NP values (metric tons per 1000 metric tons) using the H2O2 Hand Method from three laboratories (WVU, PADEP, and CONSOL) on 31 overburden samples1. Fizz ratings were determined independently by each laboratory.

WVU PADEP CONSOL Difference

Sample Fizz NP Fizz NP Fizz NP High - Low
Fe
1 1 16 1 14 0 20 6*2
2 1 19 1 21 0 28 9*
3 1 17 1 16 0 25 9*
4 1 15 1 12 3 43 31*
5 1 56 1 25 0 77 52 *
6 2 322 3 301 3 277 45*
Ca
1 3 926 3 926 3 924 2
2 3 847 2 500 3 851 351*
3 3 728 3 711 3 728 17
S
1 0 -74 0 -58 0 -24 50
2 1 31 0 41 0 71 30*
3 0 33 1 59 0 37 26
4 0 -16 0 -1 0 -3 15
5 0 18 1 16 0 18 2
Si
1 0 4 0 6 0 9 5
2 0 1 0 5 0 3 4
3 0 1 0 4 0 2 3
4 0 16 1 23 0 20 7*
5 2 64 1 58 0 54 10*
6 0 -4 0 4 0 6 10
7 0 -6 0 1 0 3 9
8 0 -9 0 1 0 0 10
9 0 -25 0 0 0 -2 25
10 0 12 0 15 0 16 4
11 1 20 1 11 0 12 9*
12 0 15 0 14 0 18 4
13 2 112 3 171 0 149 37*
14 0 9 0 13 0 11 4
15 1 24 1 24 0 21 3*
16 0 23 1 8 1 18 15*
17 1 26 1 11 1 27 15

mean difference = 26.4

1All the labs digested samples according to fizz ratings and corresponding strengths and volumes of HCl (Table 2).

All labs filtered the samples and added 5 ml of 30% H2O2 to the filtrates prior to titration and titrated to pH 7.0.

2 Indicates that the laboratories assigned a different fizz rating to this sample.